Emergent Metering

Brand

Sage Metering

Thermal mass flow meters for natural gas, biogas, flare gas, and compressed air — direct-mass measurement without pressure or temperature compensation.

About Sage Metering

Sage Metering builds thermal mass flow meters for natural gas, biogas, digester and landfill gas, flare gas, and compressed air. Thermal mass technology measures mass flow directly, so unlike volumetric meters it does not require separate pressure and temperature transmitters and flow computers to correct the reading — one instrument, one signal, no compensation chain to drift or fail.

That makes Sage meters especially well suited to dirty, wet, or variable-composition gases where volumetric meters struggle, and to low-flow conditions where differential-pressure devices lose turndown. In-situ calibration verification lets a technician confirm accuracy in the field without pulling the meter out of the line.

Emergent Metering applies Sage meters to greenhouse-gas reporting, boiler and process gas submetering, digester and landfill gas measurement for renewable-energy credit programs, and industrial natural-gas cost allocation where the utility provides only a single master meter for the whole site.

Choosing a Sage Prime configuration

SeriesElectronicsConfigurationAccuracyBest for
Sage Prime SIPIntegral — mounted at the probeIn-line or insertion±0.5% of full scale plus ±1% of readingAccessible points where the display is read at the meter
Sage Prime SRPRemote — up to 1000 feet from the probeIn-line or insertion±0.5% of full scale plus ±1% of readingPoints that are hot, high, hazardous or hard to reach

Specifications

  • Turndown of 100 to 1, with resolution as much as 1000 to 1
  • Repeatability of 0.2%
  • NIST traceable calibration
  • In-situ calibration verification, with raw calibration milliwatts displayed continuously
  • Modbus RS485 RTU standard using IEEE 32-bit floating point; BACnet optional
  • Isolated 4–20 mA output plus a pulsed output of totalized flow
  • Power draw under 2.5 watts, which is under 100 mA at 24 VDC
  • NEMA 4 enclosure, with an explosion-proof junction box available
  • No moving parts and negligible pressure drop
  • Natural gas, biogas, digester and landfill gas, flare gas and compressed air

Figures from the Sage Prime SIP and SRP datasheet.

Sage Metering FAQ

How accurate are Sage thermal mass flow meters?
Standard accuracy on the Sage Prime SIP and SRP series is ±0.5% of full scale plus ±1% of reading, with repeatability of 0.2% and a turndown of 100 to 1, with resolution as much as 1000 to 1. Enhanced accuracy is optionally available with a limited turndown. Calibration is NIST traceable.
Why choose thermal mass over a volumetric flow meter?
Thermal mass meters measure mass flow directly, so unlike volumetric meters they do not need separate pressure and temperature transmitters and a flow computer to correct the reading. That removes an entire compensation chain that can drift or fail, and it means the reading stays stable when process temperature and pressure change.
Can accuracy be verified without pulling the meter out of the line?
Yes. The Sage Prime displays its raw calibration milliwatts continuously in the corner of the display, and the in-situ calibration verification procedure checks the sensor's performance and its live zero point against the original factory value. It also confirms the sensor is clean. That gives a documented field validation without removing the meter from service.
Which gases do these meters handle?
Natural gas, biogas, digester and landfill gas, flare gas and compressed air. Thermal mass technology is particularly well suited to dirty, wet or variable-composition gases where volumetric meters struggle, and to low-flow conditions where differential-pressure devices lose turndown.
How does a Sage meter integrate with a monitoring system?
Modbus RS485 RTU is standard, using IEEE 32-bit floating point, with BACnet available as an option. There is also an isolated 4–20 mA output proportional to mass flow rate and a pulsed output of totalized flow. Power draw is under 2.5 watts, which is under 100 mA at 24 VDC.
What is the difference between the SIP and SRP series?
SIP is the integral version, with the electronics mounted at the probe. SRP is the remote version, which places the electronics up to 1000 feet away from the probe — the right choice when the measurement point is in a location that is hot, high, hazardous or simply hard to reach for a reading. Both are available in in-line and insertion configurations, and both use a NEMA 4 enclosure.

Sage Metering products

Need pricing for a project?

Send us the point count, meter types, and site details — you'll get a line-item quote covering hardware, panels, communications, and commissioning.

Ready to put energy data to work?